C320 Open-loop Vector Control Inverter

Home » Products » Frequency Inverter » C320 Open-loop Vector Control Inverter
C320 Open-loop Vector Control Inverter

Using the international advanced current control algorithm, the C320 open-loop vector control inverter can decompose the current of rotor, and can separately control the torque current and speed current. The application shows that the control performance of our inverter has already reached international advanced level.

Features
1. Its power ranges from 3.7W to 250 KW and its input voltage is 220V±20%, 380V±20% and 415V±15%.
2. With the two-line LED display, users can have convenient on-site commissioning. The open-loop vector control inverter can monitor two groups of parameters at the same time to achieve overall information about the running state.
3. Using the remote control keyboard, its stable communication distance can reach 1,000 meters.
4. With the standard built-in RS485 interface, the open-loop vector control inverter can be used together with PLC, IPC and other automatic control equipment. Many inverters can have linkage operation at the same time.
5. For the inverter with power ranges from 0KW to 18.5 KW, it has the standard built-in brake unit, and can easily adjust the braking start voltage and braking action ratio.
6. Featuring advanced current vector control algorithm and fast load responses, the inverter can achieve best output performances.
7. The open-loop vector control inverter features 150% low-frequency torque output and steady speed precision and uses the adaptive control technology and pulse width modulation (PWM) to achieve optimal control performance.
8. With the highly reliable electrical hardware design, the inverter can minimize the failure rate.
9. It can automatically check the motor parameters, and has 8 programmable multi-speed control, 6 kinds of running mode, and up to 29 kinds of frequency input channel combinations.
10. The open-loop vector control inverter can automatically check the output state. When the inverter is separated from motor, the automatic frequency reduction will stop. After installing the motor, the inverter will automatically recover its operation and has convenient remote power control.
11. It has multi-function programmable input ports, programmable relay output and the standard built-in PID regulator (it can preset frequency).
12. The inverter has the functions of flexible analog I/O, three analogue value input adjustment, two analog output and parameters duplication of the convenient operational panel.
13. Its cooling fan can choose power-on operation state or working operation state according to environmental temperature to reduce the power consumption of inverter.
14. The open-loop vector control inverter has automatic energy saving running mode to further save electricity, and voltage stabilizing running function for maximally keeping voltage stability.

Typical Application
The open-loop vector control inverter is used for CNC machine tools, manipulator, oxygen making machine, air-compressor, ceramic machine, industrial washing machine, etc.

Technical Specifications

Input Rated voltage, rated frequency 3 PH (4T# Series) 380V 50/60Hz 3 PH (2T# Series) 220V 50/60Hz 1 PH (2S# Series) 220V 50/60Hz
Permissible voltage range 3 PH (4T# Series) 300V~460V 3 PH (2T# Series) 170V~270V 1 PH (2S# Series) 170V~270V
Output Voltage 4T#Series: 0~380 V 2S#, 2T# Series: 0~220 V
Frequency 0~400Hz
Overload capacity 110% rated current for long-term; 150% rated current for 1m; 180% rated current for 2s.
Control mode V/F control, sensorless current vector control
Control characteristics Frequency setting Resolution Analog terminal input 0.1% of maximum output frequency
Digital setting 0.01 Hz
External pulse 0.1% of maximum frequency
Frequency precision Analog input Within 0.2% of maximum output frequency
Digital input Within 0.01% of setting output frequency
External pulse Within 0.1% of maximum output frequency
V/F control V/F curve (Voltage-frequency characteristics) Reference frequency can be randomly set between 5Hz to 400Hz and V/F curve with multiple joint can also be randomly set. There are three curves provided, including constant torque curve, Dec torque curve 1 and Dec torque curve 2.
Torque boost Manual set: 0.0~20.0% of rated output. Automatic torque boost can be set according to output current.
Auto current/voltage limit It will automatically check the current and voltage of motor stator during acc/dec or stable running. Based on special arithmetic, it can control the current and voltage within allowable range to ensure the minimum failure.
Sensorless vector control Voltage/frequency characteristics The open-loop vector control inverter can automatically adjust the proportion of output voltage to output frequency according to the motor parameters and unique algorithm.
Torque characteristics When the frequency is 1 Hz, the inverter will output 150% of rated torque, and features 0.1% of speed stabilization precision.
Motor parameters self-detection Without any limitation, the inverter can finish the motor parameter self-detection under static state, so as to achieve sound control effect.
Current / voltage limit The current closed-loop control can completely avoid the current impact, and has the function of overvoltage limit.
Under voltage inhibition in running It is especially suitable for the users with low network voltage and frequently fluctuated network voltage. Even the voltage is lower than permissible voltage, and the system will maintain the longest possible running time according to the unique algorithm and residue energy allocation strategy.
Typical functions Multi-speed and wobble frequency running 8 programmable multi-speed control modes, 6 running modes and 15 multi-speed control modes of terminal. Wobble frequency operation is composed of preset frequency, central adjustable frequency and state memorization and recovery after machine halt or power failure.
PID control RS485 communication The built-in PID controller can preset the frequency. It provides the standard RS485 communication and various communication protocols for choice. It has the synchronous control function.
Automatic stop after cutting off the output It can automatically check the output state. When the inverter is separated from motor, the automatic frequency reduction will stop. After installing the motor, the inverter will automatically recover its operation and has convenient remote power control.
Frequency setting Analog input DC voltage: 0~5V, 0~10V; DC current: 0~20mA
Pulse input Its amplitude value is between 5 and 30V, and its frequency is within 50.0KHz.
Digital input It can set by operation panel, RS485, UP/DW terminal, and also can set multiple combinations with analogue input.
Output signal OC output Two OC output, fault relay output (TA, TB, TC) and as many as 16 types of output mode for choice
Analog output Two 0~10V voltage or 0~20mA current signal
Automatic energy saving running According to the output current, the inverter can timely adjust the output voltage and slip compensation to ensure the motor have highest efficient operation.
Voltage stabilizing running Three ways for selection: dynamic voltage regulation, static voltage regulation, instable voltage regulation, so as to get the most stable running result.
Acc/Dec time setting 0.1S~6000min continuous setting, S curve and linear mode for choice
Braking Regenerative braking Higher than 75%
DC braking Action frequency: 0~50.0 Hz; action time: 0~20.0s or continuous action.
Typical functions Low noise running Carrier wave frequency range is1.5 KHz ~ 12.0 KHz that is continuously adjustable to minimize the motor noise.
Dec restart function The smooth restart and instantaneous-stop restart function of running motor can be achieved.
Counter It has built-in counter to facilitate the system integration.
Operating function Upper and lower frequency setting, frequency hopping operation, reversal operation limitation, RS485 communication, voltage stabilizing running, frequency increasing/decreasing control, etc.
Display Operation panel display Running state Output frequency, output current and voltage, motor speed, frequency setting, module temperature, PID setting and feedback quantity, analog I/O and so on.
Alarming The operation panel shows recent six times failure record, and last running parameter record of output frequency, setting frequency, output current, output voltage and DC voltage, module temperature and so on during last fault trip period.
Protection / alarming function Overcurrent, overvoltage, undervoltage, electronic thermal relay, overheating, short circuit, internal memory fault, etc.
 Environment Ambient temperature -10ºC to +50ºC (nonfreezing)
Ambient humidity Under 90% (non-condensing)
Ambient environment Indoor (without corrosion, inflammable gas, oil mist or dust and so on)
Altitude Lower than 1000m
Structure IP protection IP20
Cooling mode Forced cooling
Installation Wall-hanging mode

Established in 2004, SUNFAR is a professional frequency inverter manufacturer based in China which has passed ISO9001:2008 certification. We provide a wide range of inverters, including open-loop vector control inverter, plastic machine inverter, mini universal inverter, and more. We can also produce energy saving unit, multi-pump constant pressure water supply control unit, etc. to suit customers' various requirements. If you have any related need, please feel free to contact us.

Feedback Form
Other Products
  • Energy Saving Unit The energy saving unit has auto voltage and current limitation functions, making the inverter run in a stable and non-fault state for long time.
    It has various analog input and output regulation modes ...
  • Dynamic Braking Unit (DBKU) High braking capability: brake continuously for full load when braking rate is 10%; brake for 30s for full load when braking rate is 100%.
    Wide voltage range: offer two braking threshold voltage ...

Company Brief: Shenzhen Sunfar Electric Technologies Company, Ltd. is a China-based frequency inverter and energy saving system manufacturer and supplier. Sunfar has been producing the mini universal inverter, high speed inverter, energy saving unit, and dynamic braking unit, etc. since 2004. Our products are widely used in the metallurgy, papermaking, and chemical industries.